FSS FLOW SAMPLING SYSTEM

Monitor and Record Stormwater or Industrial Discharge Flow

FEATURES:

  • Ideal for wastewater, industrial, and environmental flow sampling
  • Simple to operate – no programming required
  • Lightweight and easy to carry
  • Rugged construction for harsh environments
  • Over 20 pre-programmed flume and weir tables for ease of use and flexibility
  • Scalable flow proportional sample triggering
  • Adjustable and repeatable sample volume
  • Peristaltic pump prevents sample contamination
  • Flow Data Recorder is Windows and PDA compatible
  • Open Channel Flow Monitor has an easy 4-button programming system
  • The easiest and most reliable method for collecting water samples

Flow Sampling System Product Description

Global Water's Flow Sampling System is a unique water monitoring package.  This package includes an easy-to-use lightweight composite water sampler, an open channel flow monitor with dual displays and outputs, and a data recorder that includes both Windows and PDA software, allowing easy upload of data to a laptop, desktop or PDA for transfer to spreadsheet programs.  NOTE: The Palm operating system is NOT supported.  This compact package is portable for field installation and fully customizable to meet your monitoring needs.

Composite Water Sampler
Global Water's flow-proportional composite water sampler is enclosed in a rugged, rainproof, lockable carrying container.  The composite water sampler includes a 2-gallon polyethylene wastewater sample bottle for collecting composite samples, a peristaltic sampling pump, a control panel (no programming required), and a rechargeable gel cell battery.  Also provided is a sample pickup hose and a battery charger.  Optional additions include glass sample bottles, refrigerated containers, portable ice containers and more. 

Open Channel Flow Monitor
Global Water's FC200 Open Channel Flow Monitor is reliable and accurate for measuring and totalizing open channel flows for all flumes and weirs, as well as any gravity-type open-channel flows.  The flow monitor is pre-programmed with over 20 different flume and weir characteristics and can also be programmed for your unique application.  The unit measures water depth with Global Water's highly accurate pressure transducer and instantly calculates (for display and output) water flow and totalizer values for any depth-to-flow relationship in any engineering units.  The Open Channel Flow Monitor is easily set up in the field using a unique four-button programming system. 

Flow Data Recorder
Global Water's flow data recorder includes Windows-based and PDA software, which provides many useful features, such as real time monitoring, measurement interval and engineering unit selections, station ID, and sensor calibration.  The Global Water Software makes accessing stored data and setting options easy.  The data recorder monitors and logs both flow rate and total flow for your records.  Data downloaded from the recorder can easily be opened in any PC spreadsheet program for analysis and graphic presentation. 

Flow Sampling System Specifications

Flow Sampling System Composite Water Sampler
Sample Size: 15 composite sample sizes from 50ml to 2 liters plus a Full Bottle discrete setting (Approximate sizes at 4 foot head)
Operating Temperature: 0° to +70°C
Materials:
     Enclosure: Expanded UV protected PVC
     Bottle: 2.5 gallon Polyethylene
     Pickup Hose: 15' reinforced PVC 1/4" ID polyethylene flexible tubing section with intake strainer
     Pump Tubing: Norprene 1/4" ID, 7/16” OD
Sample Pump:
     Flow Rate: 1000 ml per minute at a 4 foot head
     Type: Peristaltic
     Maximum Lift: ~20 feet
Battery: Rechargeable 5 AH Gel Cell
Battery Life: ~1 hour, continuous pumping under load
Standby: 3 months while still retaining enough power to run the pump to capacity

Flow Sampling System Open Channel Flow Monitor
Rate Display: 5 digit + decimal place, LCD
Totalizer Display: 6 digit, LCD (FSS-STD and FSS-LTS only)
Accuracy: Pressure transducer: +0.2% FS, Flow Monitor: +0.01% + the depth-flow-table error
Flow Units: CFS, GPM, m3s, MGD
Totalizer: Related to Flow Units (FSS-STD and FSS-LTS only)
Relay Contacts: (All Models)
     Voltage: 30VDC
     Current: 5A/30VDC
     Max Capacity: 150W
     Relay 1, Pulse Output: NPN to Ground, 1.0Kohm pull-up resistor (connected to sampler) (WQS-STD and WQS-LTS)
     Relay 2, Pulse Output: NPN to Ground, Open-collector (connected to datalogger and tied to totalizer scaler) (WQS-STD and WQS-LTS)
Analog Output: 4mA minimum, 20mA maximum (Flow reading)
     Resolution: 0.005mA
Power:
     FSS-STD and FSS-LTS: independent 12VDC rechargeable battery
          60mA DC normal, 100mA maximum
     120uA during sleep mode
     FSS-INT: uses the WS700 12VDC rechargeable battery
     60mA DC normal, 100mA maximum
     120uA during sleep mode

Pre-defined Tables
     Parshall: 1", 2", 3", 6", 9", 12"
     Palmer-Bowlus (4D): 4", 6", 8", 10", 12", 15"
     Weir: 45° V notch, 90° V notch, 1' rectangular, 2' rectangular
     H: 0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
     Trapezoidal: 60°
Custom Table
Equation or look up table provided at time of order.  Allow for longer lead times for custom table entry.

Flow Sampling System Datalogger
Memory: Non-volatile flash memory
Power:
     FSS-STD and FSS-LTS: independent 12VDC rechargeable battery
     FSS-INT: uses the WS700 12VDC rechargeable battery
     Standby Current: 70uA Typical
     Logging Current: 5mA Typical + sensor current
Analog Sensor Inputs: 4-20mA
     Resolution: 12-Bit, 4096 Steps
     Sensor Warm-up Time: Programmable, 0-60 Sec
     FSS-STD and FSS-INT: 6 Input channels + flow rate + battery voltage monitor
     FSS-LTS: 1 Input channels + flow rate + battery voltage monitor
Digital Inputs:
     Maximum Input Voltage: 24VDC
     Maximum Frequency: 100Hz
     Minimum Pulse Width: 2mS
     Maximum Count: 65,535 (16-Bit)
     FSS-STD and FSS-INT: Sample Event + total flow
     FSS-LTS: 1 input channel connected to totalizer
Sample Now Input: Sample-on-Demand input, software enabled (FSS-STD and FSS-INT only)
     Maximum Input Voltage: 24VDC
     Minimum Pulse Width: 2mS
Sample Modes:
     Fixed Interval Programmable from 1 Sec. to >1 Year
     High Speed 10 Samples per second
     Logarithmic Sample Rate (Approximation)
     Exception (Log only on deviation from previous reading)
Storage Capacity:
     FSS-STD and FSS-INT: 40,879 Recordings for all inputs plus time
     FSS-LTS: 81,759 Recordings for all inputs plus time stamp
     Data Overwrite: Select memory wrap or unwrap (unwrap will stop logging data once memory is full)
Communication Ports:
     FSS-STD and FSS-INT: RS-232 DB9 or USB Type B
     FSS-LTS: RS-232 4-pin circular connector
     Selectable Baud Rates: 9600, 19200, 28800, 38400, 57600, 115200
Clock: Synchronizes to the time and date of user's computer
Operating Temperature: Industrial, -40ºC to +85ºC (Battery may not apply)

Data Logger Software
Compatible with Microsoft's Windows 98, ME, 2000, NT, and XP
Windows and Excel are trademarks of the Microsoft Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included

Mechanical:
FSS-STD: (2 enclosures)
     Sampler Enclosure: 22”H X 17"W X 9"D
     Flow Logger Enclosure: 14.5”Hx10”Wx6”D
     Sampler Weight: 20lb
     Flow Logger Weight: 14.1lb
FSS-LTS: (2 enclosures)
     Sampler Enclosure: 22”H X 17"W X 9"D
     Flow Logger Enclosure: 14.5”Hx10”Wx6”D
     Sampler Weight: 20lb
     Flow Logger Weight: 13.1lb
FSS-INT:
     Enclosure: 22”H X 17"W X 9"D
     Weight: 22lb

Flow Sampling System Options

FSS-STD Flow Sampling System
Includes flow-proportional WS700 composite water sampler, FC200 open channel flow monitor, and GL500-7-2 flow data recorder.
FSS-LTS Flow Sampling System Lite
Includes flow-proportional WS700 composite water sampler, FC200 open channel flow monitor, and GL500S-2-1 flow data recorder integrated into open channel flow monitor.
FSS-INT Integrated Flow Sampling System
Includes flow-proportional WS700 composite water sampler with built in open channel flow monitor and GL500-7-2 flow data recorder.
FSS Flow Sampling System with WS750 Water Sampler
Includes flow-proportional WS750 water sampler with open channel flow monitor and GL500-7-2 flow data recorder.
PDAWL16 Deluxe PDA Package 
Handheld PDA download package for WL16 or GL500.
 Printable Version (View: 1642 | Print: 599)

Next:
FP111 & FP211 GLOBAL WATER FLOW PROBE
FL16 WATER FLOW LOGGERS
FC200 OPEN CHANNEL FLOW MONITOR
FC200-S SEWER FLOW MONITOR

Previous:
WMX101 MAGNETIC FLOW METERS
EX80 INSERTION MAGMETERS
EX100/200 ELECTROMAGNETIC FLOW SENSORS
TX80 TURBINE INSERTION FLOW METERS
TX100/200 ADJUSTABLE TURBINE FLOW SENSOR

Control
Remote Monitoring
Water Flow
Water Level
WATER QUALITY
Water Sampler
Weather
 
PT. PROLABMAS MURNI SWADAYA
Sentra Niaga Puri Indah Blok T3-10
Jakarta 11610 - Indonesia
Telp: +62 (21) 581 8000, 581 9000
Fax: +62 (21) 581 6999
 
Home  |  About Us  |  Products  |  Download  |  Support  |  Contact Us
 
   Back to top