 Tinius Olsen Heat Distortion
Home : Our Principals : TINIUS OLSEN : Tinius Olsen Heat Distortion

603 HDTM

The Model 603 HDTM is the latest generation of Tinius Olsen's digitally controlled Automatic Deflection Temperature/Vicat test equipment, capable of testing up to six different specimens simultaneously, with an automated testing sequence that proceeds according to user defined control and configuration parameters.

All testing hardware is fully complemented by Tinius Olsen developed software that turns your hardware into a sophisticated quality analysis system. Be sure to examine the software products to determine which package is right for your application.

Key Features :

  • Conforms to ISO 75, ISO 306, ASTM D648, and ASTM D1525

  • Fully automatic control of entire test cycle

  • Bath has port with an exhaust fan to remove interior oil fumes

  • Air bearing-guided loading rods for virtually friction-free load application

  • Electronic transducers integrated into the loading rod assemblies for 0.001 mm (0.0001 in) resolution of deflection or penetration

  • Loading nose and rod assemblies provide 76 grams nominal load for ISO 75 ‘flatwise’ deflection temperature tests on 4 mm x 10 mm specimens at 0.45 Mpa stress

  • Built-in heat exchanger for rapid system cooldown

  • Pneumatic station lift for easy specimen insertion and removal

  • Automatic correction for thermal expansion of test frames

  • Built-in specimen basket to catch any dislodged specimens

  • Accessories available include additional test stations, deflection temperature loading noses, Vicat loading noses and needles, weights, 64 mm span supports for ‘flatwise’ deflection temperature testing (the stations are predrilled to accept these supports)

Technical Specifications

Operating Environment  :    
Environmental Temperature Range : 60 to 100°F (15 to 38°C)
Storage Temperature Range : 14 to 115°F (-10 to 45°C)
Humidity Range : 10% to 90% non-condensing, wet bulb method
Power : standard optional voltages 220/240 VAC, 50 – 60 Hz; power must be free of spikes and surges exceeding 10% of the nominal voltage

MODEL

 

603 HDTM

TEMPERATURE RANGE

°C 23° to 300°

TEMPERATURE RAMP

°C 50° per hour or 2° per minute

TEMPERATURE DISPLAY RESOLUTION

°C 0.1

TEMPERATURE SENSOR

Platinum RTD located adjacent to the load application pont at each station

DEFLECTION/PENETRATION MEASUREMENT

LVDT

DEFLECTION/PENETRATION DISPLAY RESOLUTION

mm 0.001

COOLDOWN RATE

Maximum of 20° above cooling water temperature in 20 minutes

TEMPERATURESAFETY LIMIT

Independent dual systems using thermostatic switch in bath and keypad selectable software limiting

DIMENSIONS W x D x H

mm 965 x 695 x 560
in 38 x 27.5 x 22
WEIGHT (NET) kg 115
lb 250

REQUIRED UTILITIES

Heat Transfer Medium 14 liters (3.7 US gallons) min
Water Water supply for cooldown
Clean Air Dry air filtered to 50 microns at 40 psi (2.7 bar) min.
Power 220 ±10% V, 50/60 Hz, 1 phase, 4.5 kW

Download PDF brochure : Click Here

 Printable Version (View: 1919 | Print: 701)
Tinius Olsen Air Brinell
Tinius Olsen Bench Machines
Tinius Olsen Heat Distortion
Tinius Olsen High Force
Tinius Olsen Hydraulic
Tinius Olsen Impact System
Tinius Olsen Melt Indexer
Tinius Olsen Software
Tinius Olsen Torsion
 
PT. PROLABMAS MURNI SWADAYA
Sentra Niaga Puri Indah Blok T3-10
Jakarta 11610 - Indonesia
Telp: +62 (21) 581 8000, 581 9000
Fax: +62 (21) 581 6999
 
Home  |  About Us  |  Products  |  Download  |  Support  |  Contact Us
 
   Back to top