TABER ® Multi-Finger Scratch / Mar Tester

The TABER ® Multi-Finger Scratch / Mar Tester is used to measure the relative resistance or susceptibility of a material surface to scratching, marring, gouging, scraping, engraving and other similar physical damage not classified as ordinary wear.

The design of Taber's Multi-Finger Scratch / Mar Tester is based on the apparatus described in automotive specifications (including Ford BN 108-13; General Motors GMN3943; and Daimler-Chrysler LP-463DD-18-01) , which is commonly referred to as a five-finger (five-arm) scratch & mar tester.

The instrument includes a pneumatically driven, moveable sledge to which the test sample is mounted. The sledge moves in a linear fashion, and is operated by a control knob for one or multiple pass testing. An electronic timer displays the rate of speed, which can be controlled by reducing or increasing air pressure.

A gantry supports five independent splined-fingers, which provide a constant, vertical load on interchangeable scratch pins (1.0mm or 7.0mm diameter hemisphere). The gantry system includes a handle to raise and lower the arms. In addition, five support rests are incorporated to allow one or more arms to be moved to an upright, rest position such that the arm does not contact the specimen during testing.

Individual weights of varying loads mount to the top of each arm finger to exert a standard force on the surface of the test material. Each instrument includes a weight set of 2N, 3N, 4N, 5N, 6N, 7N, 10N, 15N and 20N loads. Other weights are available for 8N, 13N, 18N and 25N.

Although flat specimens up to 22mm thick are normally tested, the ‘free-floating' arms fingers enable you test evaluate slightly contoured specimens provided they are rigid or adequately supported. A spring-loaded specimen holder is standard and can be mounted to the end or side of the moveable sledge for greater flexibility. To mount contoured specimens, an optional set of ‘moveable' hold-down clamps is available.

 Printable Version (View: 1921 | Print: 680)
Taber Abraser
Taber Adhesion Testers
Taber Balances
Taber Glossmeter
Taber Impact Tester
Taber Linear Abraser
Taber Multi-Media Abraser
Taber Optical Micrometer
Taber Scratch - Mar Tester
Taber Scrub Abrasion
Taber Shear - Scratch Tester
Taber Software for Abraser
Taber Stiffness Tester
Taber Thickness Gauge
 
PT. PROLABMAS MURNI SWADAYA
Sentra Niaga Puri Indah Blok T3-10
Jakarta 11610 - Indonesia
Telp: +62 (21) 581 8000, 581 9000
Fax: +62 (21) 581 6999
 
Home  |  About Us  |  Products  |  Download  |  Support  |  Contact Us
 
   Back to top